Underfloor heating in a 1,300 sq ft detached home
A four-circuit underfloor heating system with room thermostats was installed in a detached home undergoing a major renovation.

The owners of a 1,300 sq ft detached home under renovation in Maple Heights wanted underfloor heating instead of radiators. We confirmed that their existing combi boiler was a condensing model suitable for low-temperature operation.
Installation steps
- A room-by-room heat loss calculation set the pipe spacing.
- Insulation and edge strip were laid, and pipes with an oxygen barrier were installed.
- A four-circuit manifold and room thermostats were connected.
- Before screeding, the circuits were pressure tested, and the pressure was maintained throughout the test.
Once the screed had dried, the system was heated up gradually over several days. We gave the homeowner a short guide to the manifold settings and thermostats.