Machine radiator flushing in a 15-radiator duplex

Chemical and machine flushing in a duplex where the upstairs radiators stayed cold at the bottom and the boiler fired too often.

VerdictAfter flushing, the difference between the top and bottom surface temperatures of the radiators dropped significantly.
Machine radiator flushing in a 15-radiator duplex

In a 15-radiator duplex in Cedar Park, the owners told us the upstairs rooms in particular were slow to warm up and the bottoms of the radiators stayed lukewarm. The system was about twelve years old and had never been cleaned.

What we did

  1. Before flushing, we measured and recorded the top and bottom surface temperature of every radiator.
  2. The power flushing machine was connected to the boiler circuit and the cleaning solution was circulated through the system.
  3. Each radiator was flushed individually with directed pressure; a heavy build-up of sludge collected in the filter.
  4. After rinsing, an inhibitor was added, the system was bled and the pressure was set.

After flushing, we repeated the same measurements and compared the results with our customer. We also balanced the upstairs radiator valves.